402.957.1231
How the AI works

The lease, watched around the clock.

On a well making two barrels a day, a week of downtime is the month's profit. The cheapest barrel we will ever produce is the one we did not lose while nobody was looking.

The problem with visiting

For a century the only way to know what a well was doing was to drive to it. A good pumper does that every day and learns a great deal from the sound of the unit, the feel of the polished rod and the look of the tank.

But a visit is a few minutes out of twenty-four hours. A well that stops an hour after the pumper leaves is down until he comes back. A pump that is pumped off at night wears itself out for weeks before anyone connects the falling production to the cause.

Bigger operators solved this long ago with automation. The equipment was priced for wells that could afford it. Sensors and wireless data have become cheap enough that it now makes sense on a well making two barrels a day, provided nobody has to be paid to sit and watch the screen. That is where the AI comes in.

What gets measured

1 2 3 4 Walking beamHorseheadGearbox and crankWellheadStock tankMotor
Where the readings come from. 1: load on the polished rod, which draws the pump card. 2: motor current and run time. 3: tank level. 4: beam position and stroke count. Drawing is schematic.
ReadingWhere it comes fromWhat it tells us
Rod loadA load cell on the polished rodThe pump card: whether the pump is filling, pumped off or disconnected
Motor current and run timeA sensor on the motor feedWhether the unit is running, how hard it is working and whether a belt is slipping
Tank levelA level sensor on the stock tankHow much the lease made, when to call the truck and whether oil is leaving when it should not be
Stroke position and countA sensor on the beamStrokes a minute and where in the stroke each load reading was taken
PowerThe meter or the driveWhat each barrel costs to lift
The pumper's gaugeHis tape, entered in the field appA human check on every sensor, every day

What the software catches

Pumped off

The pump is moving faster than oil can flow into the wellbore, so part of every stroke is wasted and the plunger slams into fluid on the way down. It burns power and beats up the rods and the pump. The fix is usually to run the well less, in shorter cycles. The software sees it in the card, works out a better cycle and proposes it.

Parted rods

The rod string has broken, so the unit is going up and down and lifting nothing. From the road it looks fine. On the card it is unmistakable: the load collapses to a thin flat loop. This is called within minutes.

Belt slip

The motor is working but the unit is not keeping up. Caught early it is a ten minute adjustment. Left alone it is a burned belt and a down well.

Tank high

The level is watched, and a high tank is flagged so a person can schedule the truck.

Power loss

The well went down because the electricity did. That is a call to the co-op, not a trip for the pumper, and knowing the difference saves a drive.

Slow change

The hardest problems to see are the gradual ones, such as a well slowly making more water. A person looking at today's number may see nothing wrong. We keep the readings so a person can compare today with earlier days.

What happens after a flag

A flag is not an action. Here is the chain.

  1. The software names it

    What it thinks is wrong, how confident it is and the readings behind the call.

  2. It drafts a response

    A work order for the pumper, a new run cycle, a call to a service crew or simply a note to keep watching.

  3. Small things go straight to the pumper

    Routine checks inside a set dollar limit are dispatched. He sees them on his phone at the start of his route.

  4. Everything else waits for a person

    Anything above the limit, anything that changes how a well is run beyond the range the engineer has set, and anything involving a rig goes to the approvals queue.

  5. The result is recorded

    What was found, what was done and whether the call was right. That record is how we check the calls.

What this means for the pumper

None of this replaces him. Sensors cannot smell a leak, hear a bearing going or notice that the cattle have been rubbing on the flowline. He is still on the lease every day.

What changes is how he spends the day. He stops driving to wells that are fine in order to find the one that is not. He arrives knowing what is wrong and what to bring. And when he says a well needs work, there is data behind him.

His readings matter as much as the sensors do. Every tank gauge he enters is compared with the level sensor. When they disagree we check both, because either one can be wrong.

What it cannot do

  • It cannot fix anything. Every repair is done by a person with tools.
  • It can be wrong. A sensor drifts, a card is misread. That is why a person approves anything that costs real money, and why every call is scored afterward.
  • It cannot make oil that is not there. Monitoring recovers barrels lost to downtime and poor run settings. It does not change the reservoir.
  • It does not run the well by itself. Changing how a controller is set, outside the range an engineer has approved, is blocked by the system.

Where this stands: monitoring begins as a five-well pilot on our first wells. The detection logic is built and tested against simulated readings. We will publish what it finds on real wells, including what it gets wrong.

Call us. A person answers.

The software does the watching and the arithmetic. It does not answer the phone, make you an offer or decide anything about your wells. People do that.

402.957.1231

Write to us
1001 Farnam St, Suite 201, Omaha, NE 68102